Newer
Older
import argparse
from datetime import datetime, timedelta
from enum import Enum
import os
import numpy as np
import pandas as pd
import pydicom
from mu_map.logging import add_logging_args, get_logger_by_args
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
class MyocardialProtocol(Enum):
Stress = 1
Rest = 2
headers = argparse.Namespace()
headers.id = "id"
headers.patient_id = "patient_id"
headers.age = "age"
headers.weight = "weight"
headers.size = "size"
headers.protocol = "protocol"
headers.datetime_acquisition = "datetime_acquisition"
headers.datetime_reconstruction = "datetime_reconstruction"
headers.pixel_spacing_x = "pixel_spacing_x"
headers.pixel_spacing_y = "pixel_spacing_y"
headers.pixel_spacing_z = "pixel_spacing_z"
headers.shape_x = "shape_x"
headers.shape_y = "shape_y"
headers.shape_z = "shape_z"
headers.radiopharmaceutical = "radiopharmaceutical"
headers.radionuclide_dose = "radionuclide_dose"
headers.radionuclide_code = "radionuclide_code"
headers.radionuclide_meaning = "radionuclide_meaning"
headers.energy_window_peak_lower = "energy_window_peak_lower"
headers.energy_window_peak_upper = "energy_window_peak_upper"
headers.energy_window_scatter_lower = "energy_window_scatter_lower"
headers.energy_window_scatter_upper = "energy_window_scatter_upper"
headers.detector_count = "detector_count"
headers.collimator_type = "collimator_type"
headers.rotation_start = "rotation_start"
headers.rotation_step = "rotation_step"
headers.rotation_scan_arc = "rotation_scan_arc"
headers.file_recon_ac = "file_recon_ac"
headers.file_recon_no_ac = "file_recon_no_ac"
headers.file_mu_map = "file_mu_map"
def parse_series_time(dicom_image: pydicom.dataset.FileDataset) -> datetime:
"""
Parse the date and time of a DICOM series object into a datetime object.
:param dicom_image: the dicom file to parse the series date and time from
:return: an according python datetime object.
"""
_date = dicom_image.SeriesDate
_time = dicom_image.SeriesTime
return datetime(
year=int(_date[0:4]),
month=int(_date[4:6]),
day=int(_date[6:8]),
hour=int(_time[0:2]),
minute=int(_time[2:4]),
second=int(_time[4:6]),
microsecond=int(_time.split(".")[1]),
)
def parse_age(patient_age: str) -> int:
"""
Parse and age string as defined in the DICOM standard into an integer representing the age in years.
:param patient_age: age string as defined in the DICOM standard
:return: the age in years as a number
"""
assert (
type(patient_age) == str
), f"patient age needs to be a string and not {type(patient_age)}"
assert (
len(patient_age) == 4
), f"patient age [{patient_age}] has to be four characters long"
_num, _format = patient_age[:3], patient_age[3]
assert (
_format == "Y"
), f"currently, only patient ages in years [Y] is supported, not [{_format}]"
return int(_num)
def get_projection(
dicom_images: List[pydicom.dataset.FileDataset], protocol: MyocardialProtocol
) -> pydicom.dataset.FileDataset:
"""
Extract the SPECT projection from a list of DICOM images belonging to a myocardial scintigraphy study given a study protocol.
:param dicom_images: list of DICOM images of a study
:param protocol: the protocol for which the projection images should be extracted
:return: the extracted DICOM image
"""
_filter = filter(lambda image: "TOMO" in image.ImageType, dicom_images)
_filter = filter(lambda image: protocol.name in image.SeriesDescription, _filter)
dicom_images = list(_filter)
if len(dicom_images) != 1:
raise ValueError(
f"No or multiple projections {len(dicom_images)} for protocol {protocol.name} available"
)
return dicom_images[0]
def get_reconstruction(
dicom_images: List[pydicom.dataset.FileDataset],
protocol: MyocardialProtocol,
corrected: bool = True,
) -> pydicom.dataset.FileDataset:
"""
Extract a SPECT reconstruction from a list of DICOM images belonging to a myocardial scintigraphy study given a study protocol.
The corrected flag can be used to either extract an attenuation corrected or a non-attenuation corrected image.
If there are multiple images, they are sorted by acquisition date and the newest is returned.
:param dicom_images: list of DICOM images of a study
:param protocol: the protocol for which the projection images should be extracted
:param corrected: extract an attenuation or non-attenuation corrected image
:return: the extracted DICOM image
"""
_filter = filter(lambda image: "RECON TOMO" in image.ImageType, dicom_images)
_filter = filter(
lambda image: protocol.name in image.SeriesDescription, dicom_images
)
if corrected:
lambda image: "AC" in image.SeriesDescription
and "NoAC" not in image.SeriesDescription,
dicom_images,
)
else:
_filter = filter(lambda image: "NoAC" in image.SeriesDescription, dicom_images)
# for SPECT reconstructions created in clinical studies this value exists and is set to 'APEX_TO_BASE'
# for the reconstructions with attenuation maps it does not exist
lambda image: not hasattr(image, "SliceProgressionDirection"), dicom_images
)
dicom_images.sort(key=lambda image: parse_series_time(image), reverse=True)
if len(dicom_images) == 0:
_str = "AC" if corrected else "NoAC"
raise ValueError(
f"{_str} Reconstruction for protocol {protocol.name} is not available"
)
return dicom_images[0]
def get_attenuation_map(
dicom_images: List[pydicom.dataset.FileDataset], protocol: MyocardialProtocol
) -> pydicom.dataset.FileDataset:
"""
Extract an attenuation map from a list of DICOM images belonging to a myocardial scintigraphy study given a study protocol.
If there are multiple attenuation maps, they are sorted by acquisition date and the newest is returned.
:param dicom_images: list of DICOM images of a study
:param protocol: the protocol for which the projection images should be extracted
:return: the extracted DICOM image
"""
_filter = filter(lambda image: "RECON TOMO" in image.ImageType, dicom_images)
_filter = filter(
lambda image: protocol.name in image.SeriesDescription, dicom_images
)
_filter = filter(lambda image: "µ-map" in image.SeriesDescription, dicom_images)
dicom_images = list(_filter)
dicom_images.sort(key=lambda image: parse_series_time(image), reverse=True)
if len(dicom_images) == 0:
raise ValueError(
f"Attenuation map for protocol {protocol.name} is not available"
)
return dicom_images[0]
if __name__ == "__main__":
parser = argparse.ArgumentParser(
description="Prepare a dataset from DICOM directories",
formatter_class=argparse.ArgumentDefaultsHelpFormatter,
)
parser.add_argument(
"dicom_dirs",
type=str,
nargs="+",
help="paths to DICOMDIR files or directories containing one of them",
)
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
parser.add_argument(
"--dataset_dir",
type=str,
required=True,
help="directory where images, meta-information and the logs are stored",
)
parser.add_argument(
"--images_dir",
type=str,
default="images",
help="sub-directory of --dataset_dir where images are stored",
)
parser.add_argument(
"--meta_csv",
type=str,
default="meta.csv",
help="CSV file under --dataset_dir where meta-information is stored",
)
parser.add_argument(
"--prefix_projection",
type=str,
default="projection",
help="prefix used to store DICOM images of projections - format <id>-<protocol>-<prefix>.dcm",
)
parser.add_argument(
"--prefix_mu_map",
type=str,
default="mu_map",
help="prefix used to store DICOM images of attenuation maps - format <id>-<protocol>-<prefix>.dcm",
)
parser.add_argument(
"--prefix_recon_ac",
type=str,
default="recon_ac",
help="prefix used to store DICOM images of reconstructions with attenuation correction - format <id>-<protocol>-<prefix>.dcm",
)
parser.add_argument(
"--prefix_recon_no_ac",
type=str,
default="recon_no_ac",
help="prefix used to store DICOM images of reconstructions without attenuation correction - format <id>-<protocol>-<prefix>.dcm",
)
add_logging_args(
parser, defaults={"--logfile": "prepare.log", "--loglevel": "DEBUG"}
)
args = parser.parse_args()
args.dicom_dirs = [
(os.path.dirname(_file) if os.path.isfile(_file) else _file)
for _file in args.dicom_dirs
]
args.images_dir = os.path.join(args.dataset_dir, args.images_dir)
args.meta_csv = os.path.join(args.dataset_dir, args.meta_csv)
args.logfile = os.path.join(args.dataset_dir, args.logfile)
if not os.path.exists(args.dataset_dir):
os.mkdir(args.dataset_dir)
if not os.path.exists(args.images_dir):
os.mkdir(args.images_dir)
global logger
logger = get_logger_by_args(args)
patients = []
dicom_dir_by_patient: Dict[str, str] = {}
for dicom_dir in args.dicom_dirs:
dataset = pydicom.dcmread(os.path.join(dicom_dir, "DICOMDIR"))
for patient in dataset.patient_records:
assert (
patient.PatientID not in dicom_dir_by_patient
), f"Patient {patient.PatientID} is contained twice in the given DICOM directories ({dicom_dir} and {dicom_dir_by_patient[patient.PatientID]})"
dicom_dir_by_patient[patient.PatientID] = dicom_dir
patients.append(patient)
_id = 1
if os.path.exists(args.meta_csv):
data = pd.read_csv(args.meta_csv)
_id = int(data[headers.id].max())
else:
data = pd.DataFrame(dict([(key, []) for key in vars(headers).keys()]))
for i, patient in enumerate(patients, start=1):
logger.debug(f"Process patient {str(i):>3}/{len(patients)}:")
# get all myocardial scintigraphy studies
studies = list(
filter(
lambda child: child.DirectoryRecordType == "STUDY"
and child.StudyDescription == "Myokardszintigraphie",
patient.children,
)
)
# extract all dicom images
dicom_images = []
for study in studies:
series = list(
filter(
lambda child: child.DirectoryRecordType == "SERIES", study.children
)
)
for _series in series:
images = list(
filter(
lambda child: child.DirectoryRecordType == "IMAGE",
_series.children,
)
)
# all SPECT data is stored as a single 3D array which means that it is a series with a single image
# this is not the case for CTs, which are skipped here
if len(images) != 1:
continue
images = list(
map(
lambda image: pydicom.dcmread(
os.path.join(
dicom_dir_by_patient[patient.PatientID],
*image.ReferencedFileID,
),
stop_before_pixels=True,
),
images,
)
)
if len(images) == 0:
continue
dicom_images.append(images[0])
for protocol in MyocardialProtocol:
if (
len(
data[
(data[headers.patient_id] == patient.PatientID)
& (data[headers.protocol] == protocol.name)
]
)
> 0
):
logger.info(
f"Skip {patient.PatientID}:{protocol.name} since it is already contained in the dataset"
)
continue
try:
projection_image = get_projection(dicom_images, protocol=protocol)
recon_ac = get_reconstruction(
dicom_images, protocol=protocol, corrected=True
)
recon_noac = get_reconstruction(
dicom_images, protocol=protocol, corrected=False
)
attenuation_map = get_attenuation_map(
dicom_images, protocol=protocol
)
except ValueError as e:
logger.info(f"Skip {patient.PatientID}:{protocol.name} because {e}")
continue
recon_images = [recon_ac, recon_noac, attenuation_map]
# extract date times and assert that they are equal for all reconstruction images
datetimes = list(map(parse_series_time, recon_images))
_datetimes = sorted(datetimes, reverse=True)
_datetimes_delta = list(map(lambda dt: _datetimes[0] - dt, _datetimes))
_equal = all(
map(lambda dt: dt < timedelta(seconds=300), _datetimes_delta)
)
assert (
_equal
), f"Not all dates and times of the reconstructions are equal: {datetimes}"
# extract pixel spacings and assert that they are equal for all reconstruction images
_map_lists = map(
lambda image: [*image.PixelSpacing, image.SliceThickness],
recon_images,
_map_lists = map(
lambda pixel_spacing: list(map(float, pixel_spacing)), _map_lists
_map_ndarrays = map(
lambda pixel_spacing: np.array(pixel_spacing), _map_lists
pixel_spacings = list(_map_ndarrays)
_equal = all(
map(
lambda pixel_spacing: (
pixel_spacing == pixel_spacings[0]
).all(),
pixel_spacings,
)
)
assert (
_equal
), f"Not all pixel spacings of the reconstructions are equal: {pixel_spacings}"
pixel_spacing = pixel_spacings[0]
# extract shapes and assert that they are equal for all reconstruction images
lambda image: [image.Rows, image.Columns, image.NumberOfSlices],
recon_images,
)
_map_lists = map(lambda shape: list(map(int, shape)), _map_lists)
_map_ndarrays = map(lambda shape: np.array(shape), _map_lists)
shapes = list(_map_ndarrays)
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
_equal = all(map(lambda shape: (shape == shapes[0]).all(), shapes))
# assert _equal, f"Not all shapes of the reconstructions are equal: {shapes}"
# print(shapes)
shape = shapes[0]
# exctract and sort energy windows
energy_windows = projection_image.EnergyWindowInformationSequence
energy_windows = map(
lambda ew: ew.EnergyWindowRangeSequence[0], energy_windows
)
energy_windows = map(
lambda ew: (
float(ew.EnergyWindowLowerLimit),
float(ew.EnergyWindowUpperLimit),
),
energy_windows,
)
energy_windows = list(energy_windows)
energy_windows.sort(key=lambda ew: ew[0], reverse=True)
# re-read images with pixel-level data and save accordingly
projection_image = pydicom.dcmread(projection_image.filename)
recon_ac = pydicom.dcmread(recon_ac.filename)
recon_noac = pydicom.dcmread(recon_noac.filename)
attenuation_map = pydicom.dcmread(attenuation_map.filename)
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
pydicom.dcmwrite(
os.path.join(
args.images_dir,
f"{_id:04d}-{protocol.name.lower()}-{args.prefix_projection}.dcm",
),
projection_image,
)
pydicom.dcmwrite(
os.path.join(
args.images_dir,
f"{_id:04d}-{protocol.name.lower()}-{args.prefix_recon_ac}.dcm",
),
recon_ac,
)
pydicom.dcmwrite(
os.path.join(
args.images_dir,
f"{_id:04d}-{protocol.name.lower()}-{args.prefix_recon_no_ac}.dcm",
),
recon_noac,
)
pydicom.dcmwrite(
os.path.join(
args.images_dir,
f"{_id:04d}-{protocol.name.lower()}-{args.prefix_mu_map}.dcm",
),
attenuation_map,
)
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
row = {
headers.id: _id,
headers.patient_id: projection_image.PatientID,
headers.age: parse_age(projection_image.PatientAge),
headers.weight: float(projection_image.PatientWeight),
headers.size: float(projection_image.PatientSize),
headers.protocol: protocol.name,
headers.datetime_acquisition: parse_series_time(projection_image),
headers.datetime_reconstruction: datetimes[0],
headers.pixel_spacing_x: pixel_spacing[0],
headers.pixel_spacing_y: pixel_spacing[1],
headers.pixel_spacing_z: pixel_spacing[2],
headers.shape_x: shape[0],
headers.shape_y: shape[1],
headers.shape_z: shape[2],
headers.radiopharmaceutical: projection_image.RadiopharmaceuticalInformationSequence[
0
].Radiopharmaceutical,
headers.radionuclide_dose: projection_image.RadiopharmaceuticalInformationSequence[
0
].RadionuclideTotalDose,
headers.radionuclide_code: projection_image.RadiopharmaceuticalInformationSequence[
0
]
.RadionuclideCodeSequence[0]
.CodeValue,
headers.radionuclide_meaning: projection_image.RadiopharmaceuticalInformationSequence[
0
]
.RadionuclideCodeSequence[0]
.CodeMeaning,
headers.energy_window_peak_lower: energy_windows[0][0],
headers.energy_window_peak_upper: energy_windows[0][1],
headers.energy_window_scatter_lower: energy_windows[1][0],
headers.energy_window_scatter_upper: energy_windows[1][1],
headers.detector_count: len(
projection_image.DetectorInformationSequence
),
headers.collimator_type: projection_image.DetectorInformationSequence[
0
].CollimatorType,
headers.rotation_start: float(
projection_image.RotationInformationSequence[0].StartAngle
),
headers.rotation_step: float(
projection_image.RotationInformationSequence[0].AngularStep
),
headers.rotation_scan_arc: float(
projection_image.RotationInformationSequence[0].ScanArc
),
headers.file_recon_ac: "filename_recon_ac.dcm",
headers.file_recon_no_ac: "filename_recon_no_ac.dcm",
headers.file_mu_map: "filanem_mu_map.dcm",
}
_id += 1
row = pd.DataFrame(row, index=[0])
data = pd.concat((data, row), ignore_index=True)
data.to_csv(args.meta_csv, index=False)